    Description

    US New MS400 touch Multi-parameter patient simulator,ECG simulator,Resp Temp IBP
    Introduction
    MS400 Multiparameter Simulator is a portable device, features in  small volume and light weight. It can simulate accurately 12-lead ECG,  Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested  in where the monitor is used.
    Features
    Simulate 35 kinds of arrhythmia (including Atrial, Ventricular,  Premature Beat and Conduction Defects) and pacemaker waveforms (including  Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture,  Non Function).
    Simulate four-channel IBP data.
    Simulate respiration signal with adjustable respiration rate, impedance and  baseline impedance, and three kinds of apnea data.
    Simulate four kinds of temperature data.
    Simulate square wave, triangle wave, pulse wave and sine wave with  adjustable frequency.
    Simulate standard ECG calibration, adult and pediatric ECG signal.
    ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG  database, other ECG database and user-defined waveform data stored in TF card  can be displayed by the simulator and exported to the equipments to be  tested.
    Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy  to operate.
    Power supply: rechargeable lithium battery or linear adapter, which reduces  interference.
    Optional operation modes: keys and touch screen.
    Parameters:
    ECG
    Conventional: All leads have the same voltage with  the II-lead as the reference
    Amplitude: 0.5,1.0,1.5 and 2.0mV
    ECG Rate:  15,20,25,30,40,60,80,100,120,140,160,180
    200,220,240,260,280,300,320,340 and 350  BPM
    ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
    The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
    Arrhythmia
    Atrial: Atrial Fib(coarse), Atrial fib(fine),  Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm,  Supraventricular Tachycardia
    Ventricular: Vent Fib (coarse), Vent Fib (fine),  PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy,  Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    Premature  Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus,  PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
    Conduction  Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart  Block, Right Bundle Branch Block, Left Bundle Branch Block
    Four IBP Channels
    The default: 00/00mmHg
    Dynamic  IBP(unit: mmHg)
    Channel 1:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right  Ventricle: 25/00
    Channel 2:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right  Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery:  25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 3:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right  Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery:  25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 4:
    Auto  Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
    Man  Swan-Ganz: press ENTER key to change every time
    Static-Pressure  Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100,  150, 200 and 250mmHg
    Channel 3: 0, 20, 40, 60, 80 and 100mmHg
    Channel 4:  P4 tracks the static pressure levels of P3
    Respiration
    Respiration Rate: 0 (Apnea), 15, 20, 30, 40,  60, 80, 100, 120 and 150 R/MIN
    Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    Baseline  impedance: 500, 1000, 1500, 2000Ω
    Apnea: 12 s, 22 s, 32 s
    Temperature
    Four temperature: 0℃(32°F), 24℃( 75°F),  37℃(98.6°F), 40℃(104°F)
    Accessories
    Standard accessories 9V/1A(CE) power adapter, an User manual, a  packaging box, a plastic packaging.
    Optional accessories a power  adapter(15V/1A)(UL), a power adapter(15V/1A), a temperature cable, an IBP cable,  a CD disk(including a case conversion software)
    Physical  characteristic
    Dimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H)
    Net  weight about 1.4kg
    Buy safe products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be  subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA  regulation, we will verify your status as an authorized purchaser of  this item before shipping of the item.
    The Fingertip Pulse Oximeter is registered on the Australian Register of  Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of  United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that  is FDA 510K Approved
    International Buyer--Please note:
    Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
    We are the manufacturer of medical equipment for 17 years, the following are our main products:
    ECG /  ECG holter   EEG / EEG Holter      B-ultrasound
    Patient Monitor      Fetal doppler             Fetal Monitor
    Spo2 Monitor          Stethoscope              Medical Image...
    .
    Agent in the world!
    We are look for partners in the world now!
    Do you want  to become our agent in you conutry?
    Join US!
    Skype:xuebox3
    contec.med.mary at hotmail.com
    Only English User Manual,Please contact us if you need other language version.thank you